BA-SB-TX5-TS

 

SPECIFICATIONS:


Frequency: S-BAND ( 4 selectable frequencies in same device)
Frequency Stability ± 5 ppm max (-35°c ÷ +72°c)
Power Output: 5W min
Output Impedance: 50 Ohm ,VSWR 2:1 max
Output Impedance: 50 Ohm, VSWR 1.5:1 max
Spurious, Harmonics: 50 dBc.
Deviation: tunable via manual trimmer 0.7MHz ÷ 3.5MHz
Frequency Response: Set to TBD MHz by internal Filter. ( FACTORY SET )
Input modulation impedance: 120 oHm ( For RS422)
Supply Voltage: 8 ÷ 12 Vdc (Reverse voltage protection, no damage: 35V)
Reverse polarity voltage protection: YES
Current consumption: 35W max



ENVIRONMENTAL:


Temperature:

-40deg. C to +72deg. C

Vibration: random , 12grms from 20 to 2000Hz ( 3 axis) , 15 minutes
Shock: 100g, 15 ms ,
Altitude:

No restrictions.

Humidity: 90%



MECHANICAL:


Size: 76 X 51 X 19mm (excluding connectors)
Weight: 155gr
Connectors:

RF –SMA FEMALE ,

15 PIN MDM –

  1. Mod in TTL or RS422 (+)
  2. Mod in RS422 ( -) or contact to pin 3 ref 2.5V ( used in TTL mode)
  3. ref 1.65V
  4. Supply returned/ GND
  5. Supply voltage
  6. NC
  7. NC
  8. GND
  9. Power HIGH/LOW ( N.C – HIGH, GND-LOW ( Half Power ±1dBm)*
  10. POWER DOWN ( N.C. – ON , GND – OFF )**
  11. GND
  12. Frequency Control 1 ( NC/Short)*
  13. Frequency Control 2 (NC /Short)*
  14. NC
  15. GND

NOTE: * PULL UP TO INTERNAL 5V. ** PULL UP TO INTERNAL SUPPLY.

Name plate ( On top panel) :

BA Logo, Model #, Serial number, Date of Production ( WW, Year).



OTHER:


Replace ability: Each unit can be replaced with another no need of calibration.
Documents:

Each unit supplied with C.O.C and ATR.



MECHANICAL DRAWING: